Single-stage pump units in compact design with nominal performances as per EN 733. Suction and discharge orifices are arranged in line with each other for direct installation in the pipe work. Electric motor and pump do not have a common shaft, standard motors as per list are applied. The back pull out construction permits the dismounting of the complete pull-out unit without removing the pump casing out of the pipe work. The separate pump shaft and motor shaft connected by a plug-in coupling make possible to dismount resp. replace the motor without touching the pump.
In the course of the development of heat transfer installations and their liquids, the standard DIN 4754 has been compiled. This standard determines, among other things, safety requirements for the operation of pumps in hot oil circuits. Volute pumps in accordance with EN 733/DIN 24255 are also generally accepted for this specification.
ABS offers SIHI’s Heat Transfer pumps for Hot Water and Hot Oil:
for Hot Water:
for Hot Oil:
When developing the unit construction type volute pumps of series ZTI, the main objective has been to turn out a number of floor space saving, easy-installation types especially adapted to the circulation of mineral and synthetic heat carriers in primary, secondary and tertiary circuits. Besides these units can advantageously be used as main circulating pumps in heat exchangers of compact design where they, owing to their constructional features, offer brand-new possibilities to the plant manufacturer for the layout of a system.
Flow rate: up to 200 m³/h
Head: up to 60 m
Speed: max. 3,600 rpm
Temperature: max. 350 °C
Casing pressure: up to 16 bar
Shaft seal: mechanical seal
Material: nodular iron